What Is Galvanized Steel? Hot-Dip Coating Explained

Galvanized steel is carbon steel with a protective zinc coating. Learn how hot-dip galvanizing works and what G30 through G235 coating weights mean.

Updated October 2026 5 min read By the ASA team

On this page
  1. How zinc protects steel
  2. Continuous hot-dip sheet vs batch hot-dip galvanizing
  3. Coating designations G30 to G235
  4. Galvanized vs galvannealed vs Galvalume
  5. Welding, painting and white rust
  6. Galvanized and coated steel from ASA

Galvanized steel is carbon steel coated with zinc to protect it from rust. The zinc acts as a barrier and also corrodes sacrificially in place of the steel, so even scratches and cut edges stay protected for a time. Most galvanized steel is made by hot-dip galvanizing, either on a continuous line for sheet (ASTM A653) or by dipping finished parts in a batch kettle (ASTM A123).

This guide explains the two hot-dip methods, how coating designations like G60 and G90 work, how galvanized compares with galvannealed and Galvalume, and what to watch for when welding, painting and storing it.

How zinc protects steel

A zinc coating protects steel in two ways. First, it seals the surface from moisture and oxygen. Second, zinc is more electrochemically active than iron, so where the coating is scratched or the edge is exposed, the surrounding zinc corrodes first and protects the bare steel. This is called galvanic or cathodic protection.

Over time zinc reacts with the air to form a dull gray layer of zinc carbonate, called the patina, which slows further corrosion. Because the zinc is consumed gradually, service life is roughly proportional to coating thickness in a given environment. Heavier coatings last longer, which is why coating weight is the main thing to specify.

Continuous hot-dip sheet vs batch hot-dip galvanizing

The term “galvanized” covers two quite different products. The difference matters when you are choosing material for a part that will be cut, formed and welded.

Continuous hot-dip galvanized sheet (ASTM A653)

Steel coil is cleaned, annealed and run through a molten zinc bath at line speed, then air knives wipe the coating to a controlled weight. A small amount of aluminum in the bath limits the brittle zinc-iron alloy layer, so the coating stays thin, bright and ductile enough to bend, roll form and draw. ASTM A653 sheet is sold by coating designation (G30, G60, G90 and so on) and is the material used for ductwork, enclosures, panels and light framing.

Batch hot-dip galvanizing after fabrication (ASTM A123)

Here the part is fabricated first, from bare steel, then cleaned, fluxed and dipped in a kettle of molten zinc. The zinc reacts with the steel to build several zinc-iron alloy layers topped by pure zinc. Batch coatings are typically much thicker than continuous sheet coatings and cover welds, inside corners and cut edges. ASTM A123 sets minimum coating thickness by material category and steel thickness. Fasteners and small hardware are galvanized to ASTM A153.

FeatureContinuous sheet (A653)Batch after fabrication (A123)
When coatedBefore fabrication, as coilAfter fabrication, as finished part
Typical productsSheet and light gauge coilStructural shapes, plate, weldments, assemblies
Coating thicknessThin, tightly controlledThicker, varies with steel chemistry
Cut edges and weldsExposed after cutting or weldingCoated
FormabilityGood; can be bent and formedCoating can crack if the part is bent after

Coating designations G30 to G235

In ASTM A653, the “G” designation states the minimum total coating weight on both sides of the sheet, in ounces per square foot, multiplied by 100. G90 means at least 0.90 oz/ft² of zinc total, both sides combined. The triple spot test (TST) averages three samples across the width; the single spot test (SST) is the minimum for any one sample.

DesignationMin total, triple spot (oz/ft²)Min total, single spot (oz/ft²)
G300.300.25
G400.400.30
G600.600.50
G900.900.80
G1151.151.00
G1401.401.20
G1651.651.40
G1851.851.60
G2102.101.80
G2352.352.00

As a rule of thumb, 1 oz/ft² of zinc is about 1.7 mils (43 µm) thick. Since the designation is the total for both sides, divide by two for the approximate coating on each face: G90 works out to roughly 0.76 mil (19 µm) per side. Metric sheet uses Z designations in grams per square meter; G90 corresponds roughly to Z275.

G60 and G90 are the most commonly specified weights. G90 is the usual choice for outdoor and humid exposure; see G90 galvanized steel for its specs and uses. Note that galvanized sheet gauge numbers map to slightly thicker decimals than uncoated sheet, so check a sheet metal gauge chart before ordering by gauge.

Galvanized vs galvannealed vs Galvalume

CoatingWhat it isBest for
Galvanized (A653, G designations)Essentially pure zinc, bright or spangledGeneral corrosion protection, formed parts
Galvannealed (A653, A designations such as A40, A60)Zinc coating heat treated into a zinc-iron alloy, matte grayParts that will be painted or spot welded
Galvalume (ASTM A792, AZ designations)Aluminum-zinc alloy, about 55% aluminumRoofing, siding and long life atmospheric exposure

Galvannealed sheet is reheated right after coating so iron diffuses into the zinc. The result has excellent paint adhesion and spot welds well, but its coatings are usually lighter than galvanized, so it offers less protection if left unpainted. Galvalume generally outlasts galvanized in atmospheric exposure, though it gives less sacrificial protection at cut edges and should not be used in contact with wet concrete.

Welding, painting and white rust

Welding galvanized steel

Galvanized steel can be welded, but zinc vaporizes well below the melting point of steel. The fumes can cause metal fume fever, so good ventilation or fume extraction is required. Zinc can also cause porosity and spatter, so many shops grind the coating back from the joint before welding. After welding, the bare area should be repaired with a zinc rich paint or other method described in ASTM A780.

Painting and powder coating

New galvanized sheet usually carries a passivation treatment or light oil that resists paint. Surfaces need cleaning and a suitable pretreatment before paint or powder coat. Galvanizing plus a paint system, often called a duplex system, lasts longer than either one alone. Galvannealed is the easier substrate when parts will always be painted.

White rust (wet storage stain)

White rust is a white, powdery zinc corrosion product that forms when moisture is trapped between tightly stacked sheets or nested parts without air flow. Light staining is mostly cosmetic, but heavy white rust consumes coating. Prevent it by keeping material dry and under cover, storing bundles off the ground and slightly inclined so water drains, and separating wet sheets promptly so they can dry.

Tip: If galvanized sheet arrives wet or is caught in rain, break the bundle and let the sheets dry with air between them. Waiting a few days can turn a surface stain into coating loss.

Galvanized and coated steel from ASA

American Steel & Aluminum stocks ASTM A653 galvanized sheet, mainly in G90, along with galvannealed (A40, A60), Galvalume (ASTM A792 AZ40) and aluminized (A463) steel in its flat-rolled sheet and plate line. ASA’s leveling and cut-to-length line processes coated steel from 24 to 11 gauge in widths from 14 to 72 in, and parts can be laser cut, formed and welded in house.

Frequently asked questions

How long does galvanized steel last?

Service life depends mostly on coating thickness and the environment. Zinc wears away faster in industrial, coastal and wet locations than in dry rural or indoor settings. Because the zinc is consumed gradually, doubling the coating weight roughly doubles the time to first rust. Thick batch galvanized coatings on structural steel generally outlast the thinner coatings used on continuous sheet.

Is galvanized steel the same as stainless steel?

No. Galvanized steel is ordinary carbon steel with a zinc coating on the surface, and its protection lasts only as long as the zinc does. Stainless steel is an alloy with at least 10.5% chromium throughout the metal, so it has no coating to wear off. Galvanized costs much less, while stainless resists corrosion longer in harsh environments.

Can you cut galvanized steel without ruining the coating?

Cutting exposes bare steel at the edge, but the nearby zinc protects small exposed areas through galvanic action, so thin sheet edges usually hold up well in normal exposure. Laser, shear and punch cuts all work. For thick parts or harsh environments, fabricate first and batch galvanize afterward, or touch up cut edges with zinc rich paint.

What does the spangle on galvanized steel mean?

Spangle is the crystal pattern that forms as the zinc coating solidifies on the sheet. Its size depends on bath chemistry and cooling and has no meaningful effect on corrosion resistance. Regular spangle is common for unpainted parts, while minimized spangle gives a smoother, more uniform surface that is usually preferred when the sheet will be painted.

Is galvanized steel safe to weld?

It can be welded safely with proper controls. Heating zinc releases zinc oxide fumes that can cause metal fume fever, a short term flu-like illness. Use local fume extraction or respiratory protection, and remove the coating from the weld area when practical. After welding, restore corrosion protection on the heated area with zinc rich paint or another approved repair method.

Material, processing and fabrication from one supplier

Send a drawing or a material list and the ASA team will quote it from stock.