On this page
G40 galvanized steel is hot-dip galvanized sheet with a minimum of 0.40 oz/ft² of zinc, measured as the total on both sides by the ASTM A653 triple spot test. That is roughly 0.34 mil (9 µm) of zinc per side, a light coating meant for dry interior service or for parts that will be painted.
G40 sits near the bottom of the A653 coating range, below the more common G60 and G90. It costs less and still protects steel through storage, fabrication and years of indoor use, but it has little reserve for weather, condensation or washdown.
What ASTM A653 requires for G40
The “G” designation names the coating, and the number gives the minimum total weight on both surfaces in hundredths of an ounce per square foot. A653 checks it three ways:
| A653 check | G40 minimum |
|---|---|
| Triple spot test, total both sides | 0.40 oz/ft² |
| Triple spot test, one side | 0.12 oz/ft² |
| Single spot test, total both sides | 0.30 oz/ft² |
The triple spot test averages samples taken from the center and both edges of the sheet width, while the single spot test is the floor for any one sample. The one-side minimum stops a mill from putting nearly all of the zinc on one face. In metric terms, G40 corresponds roughly to Z120 (about 120 g/m² total).
How thick is G40 zinc?
Using the common conversion of 1 oz/ft² of zinc to about 1.7 mils (43 µm), the 0.40 oz/ft² total works out to about 0.68 mil (17 µm), or roughly 0.34 mil (9 µm) per side with an even split. That is less than half the zinc on G90. The coating is included in the nominal gauge thickness of galvanized sheet, so a 20 gauge G40 sheet is not thicker than a 20 gauge G90 sheet; it simply has more steel and less zinc in the same decimal thickness.
Tip: Do not confuse G40 with A40. Both carry 0.40 oz/ft² total, but A40 is galvannealed: the zinc has been heat treated into a matte zinc-iron alloy for painting and spot welding. Write the full designation on the purchase order.
G40 compared with G30 and G60
G40 is usually chosen as a step up from the lightest commercial coating or a step down from G60 to save cost on parts that will never see moisture.
| Property | G30 | G40 | G60 |
|---|---|---|---|
| Min total, triple spot | 0.30 oz/ft² | 0.40 oz/ft² | 0.60 oz/ft² |
| Min total, single spot | 0.25 oz/ft² | 0.30 oz/ft² | 0.50 oz/ft² |
| Approx zinc per side | 0.26 mil (6 µm) | 0.34 mil (9 µm) | 0.51 mil (13 µm) |
| Approx metric equivalent | Z90 | Z120 | Z180 |
Because zinc is consumed at a fairly steady rate in a given environment, time to first red rust scales roughly with coating weight. G60 carries 50% more zinc than G40 and should last about 50% longer in the same exposure. The cost difference between them is usually small compared with the cost of replacing a rusted part, so G40 makes sense mainly where exposure is truly mild or a paint system will do most of the work.
Where G40 galvanized steel is used
G40 belongs in conditioned or protected spaces. Typical applications include:
- Nonstructural interior framing: drywall studs and track for interior partitions. ASTM C645, the standard for nonstructural steel framing, has long used G40 as its minimum coating, with provisions for alternative coatings shown to perform equivalently (often labelled G40EQ). Check the project specification, since many architects call for G60 or heavier.
- Appliance and equipment internals: chassis, brackets, shields and back panels that live inside a cabinet.
- Electrical and electronics hardware: interior mounting plates, panels and covers in dry rooms.
- Shelving, furniture and fixtures: parts that are painted or powder coated and used indoors.
- Light fixture housings and trim: formed parts where the zinc mainly prevents rust during storage and handling before finishing.
What these parts share is low moisture. In a dry building, zinc corrodes very slowly, so even a light coating can last for decades. The same coating on an unheated loading dock or rooftop would show red rust far sooner.
Where to step up from G40
- Exterior walls, crawl spaces, parking structures and unconditioned attics, where condensation forms
- Structural framing members, which framing standards commonly require at G60 minimum
- HVAC duct and equipment, which is usually specified at G60 or G90 galvanized steel
- Anything outdoors, near the coast or exposed to cleaning chemicals
Fabricating and finishing G40 sheet
A light coating has one fabrication advantage: there is less zinc to deal with. G40 bends, roll forms and draws well because the thin coating stays adherent through tight radii, and it produces less zinc fume and less electrode pickup during resistance spot welding than heavier coatings. Laser cutting, punching and shearing all work, and the thin zinc layer burns back only a small distance from a laser-cut edge.
The trade-off is edge and scratch protection. Galvanic protection of a cut edge depends on the zinc nearby, and G40 has less of it to spend. On indoor parts that is rarely a problem. On parts that will be painted, the paint film carries the long-term protection and the zinc helps prevent undercutting where the paint is damaged.
For painted or powder coated parts, ask whether the sheet will carry a chemical passivation treatment from the mill. Passivated galvanized sheet resists white rust in transit but can interfere with pretreatment and adhesion, so finishers often prefer unpassivated or lightly oiled material. Agree on that before the order is placed. ASA’s powder coating service can finish galvanized parts in house.
How to order G40 galvanized steel
A complete callout names five things: specification, base steel designation, coating, surface treatment and thickness. A typical line reads: ASTM A653 CS Type B, G40, passivated, 20 gauge (0.0396 in). Commercial Steel (CS) Type B is the usual default for brackets and panels. Choose Forming Steel (FS) for severe bends and roll forming, or Structural Steel (SS) with a grade when the design relies on a minimum yield strength.
Also specify spangle if appearance matters. Minimized spangle gives a smoother surface for painting, while regular spangle is fine for hidden parts. Gauge decimals for galvanized sheet differ from uncoated sheet, so confirm thickness in inches against the sheet metal gauge chart.
If the drawing gives a coating thickness in microns or mils rather than a G designation, convert it before quoting. Requirements expressed per side, as some international drawings do, are easy to misread as totals.
Buying G40 galvanized from ASA
American Steel & Aluminum stocks ASTM A653 galvanized sheet, mainly in G90, as part of its flat-rolled sheet and plate line, with mill certifications and full material traceability available. Coated steel from 24 to 11 gauge can be leveled and cut to length, with PVC film or interleaving between sheets when the surface matters, then laser cut, formed and powder coated in house. Call 1-800-933-7833 or request a quote with your coating designation and thickness to check G40 availability.
Frequently asked questions
Is G40 galvanized steel good enough for outdoor use?
Generally not on its own. G40 has a light zinc layer, about 0.34 mil per side, which wears through relatively quickly in rain, condensation or salty air. Outdoor sheet metal is normally specified at G90 or heavier. G40 can work outside only when a durable paint or powder coat system carries most of the corrosion protection and is maintained.
What is G40EQ?
G40EQ is a label used on some nonstructural framing to indicate a coating that the producer says performs equivalently to G40 in corrosion testing, rather than one that meets the G40 zinc weight itself. ASTM C645 allows equivalent coatings under defined conditions. If a project specification calls for true G40 or heavier, confirm what the supplier is providing before accepting an EQ product.
How much zinc is on a square foot of G40 sheet?
At least 0.40 ounces of zinc per square foot of sheet, counting both surfaces together, as an average of three test samples across the width. No single sample may fall below 0.30 ounces, and each face must carry at least 0.12 ounces. In metric terms that is roughly 120 grams of zinc per square meter of sheet.
Can G40 galvanized steel be welded?
Yes. Its light coating is easier to weld than heavier galvanized sheet because there is less zinc to vaporize, which means less spatter, porosity and electrode wear in spot welding. Fume extraction is still needed, since zinc oxide fumes can cause metal fume fever. Touch up the heated zone with zinc rich paint if the part will see any moisture.
Why choose G40 instead of G60?
Cost and fit for purpose. G40 uses less zinc, so it is usually slightly cheaper, and for dry interior parts or parts that will be painted it offers enough protection. It also welds and forms with a little less trouble from the coating. Where moisture is likely, the small saving rarely justifies the shorter life compared with G60.