Structural Steel for Commercial Construction: Shapes and Processing

How steel-framed commercial buildings go together, which shapes each member uses, how columns, beams and braces are processed, and the specs that govern an order.

Updated October 2026 5 min read By the ASA team

On this page
  1. How a steel-framed commercial building is organized
  2. Which shapes go where
  3. Processing by member type
  4. Connections, holes and bolts
  5. Specifications that shape the order
  6. Structural steel processing at ASA

Structural steel for commercial construction is mostly wide flange beams and columns rolled to ASTM A992, hollow structural sections (HSS) for columns and braces, angles and channels for secondary framing, and plate for base plates and connections. Offices, retail centers, schools, hospitals and warehouses are framed this way because steel erects quickly, spans long distances and can be modified later.

Each of those members arrives on site already cut to length, drilled, coped and fitted with its connection material. Understanding how the building is organized makes it easier to see why each piece is processed the way it is.

How a steel-framed commercial building is organized

Gravity framing

Columns carry floor and roof loads down to the foundations. Girders span between columns, and beams span between girders at regular spacing to support the floor deck. In multistory buildings, the deck is usually composite: concrete poured on corrugated steel deck, tied to the beams by welded shear studs so beam and slab act together. Bays in the range of 30 by 30 ft (9 by 9 m) are typical for office floors.

Single-story retail, warehouse and school buildings often use open web steel joists and joist girders for the roof instead of rolled beams, because they are light and economical over long spans.

Lateral framing

Wind and seismic loads are resisted by braced frames, with diagonal HSS or angle braces, or by moment frames with rigid beam to column connections. Braced frames use less steel; moment frames keep bays open for doors, windows and storefronts. Many buildings combine both.

Which shapes go where

MemberCommon shapeTypical specification
ColumnsW-shapes (often W10, W12, W14) or square HSSASTM A992; A500 for HSS
Floor beams and girdersW-shapesASTM A992
Vertical bracesHSS, double angles or WTASTM A500, A36, A992
Lintels and shelf anglesAngles, sometimes with plateASTM A36
Roof frames, screens and openingsChannels, angles, HSSASTM A36, A500
Base, cap and connection platesPlateASTM A36 or A572 Grade 50

A W-shape designation gives nominal depth and weight: a W14x90 is nominally 14 in deep and weighs 90 lb per foot (134 kg/m). Rolling tolerances for depth, flange width, camber and sweep are set by ASTM A6, so drawings rely on the published designation and detailers allow for mill variation at connections. For a comparison of the two most common grades, see A36 vs A992 steel.

Processing by member type

Columns

Columns are cut to length and fitted with a welded base plate, a cap plate at the roof and splice plates where a column continues to the next tier. Connection holes or welded shear tabs go at each floor level. US federal safety rules for steel erection (OSHA 29 CFR 1926 Subpart R) require columns to be anchored with at least four anchor rods, and perimeter columns to carry holes or attachments for perimeter safety cables, so these details appear on most column drawings.

Beams and girders

Beams are sawn to length, coped where they frame into a girder at the same top elevation, and drilled for clip angles or punched to match a shear tab. Composite floor beams are often cambered in the shop so they end up level once the wet concrete is placed. Shear studs are frequently welded in the field through the deck, so top flanges that receive studs are left unpainted.

Braces

HSS braces are slotted at each end to slip over a gusset plate, then welded. A tube laser can cut the slot, the end profile and any bolt holes in one setup. Angle braces are punched and sheared or sawn.

Miscellaneous metals

Every commercial job also has lintels, shelf angles for masonry, embed plates with headed studs cast into concrete, stair stringers, ladders and roof frames for mechanical units. These items are often specified separately from the structural frame and are small, numerous and easy to lose track of, so they benefit from clear piece marks and kitted delivery.

Sequencing and delivery

Steel is erected in sequences, usually by area and tier, and the erector needs pieces in that order. Processed members are typically marked with the piece mark from the erection drawings, bundled by sequence and shipped so the first pieces off the truck are the first ones lifted. Columns and base plates come first, followed by girders, beams and bracing for each tier, with miscellaneous metals released to suit the trades that install them.

Connections, holes and bolts

Most beam connections in commercial buildings are simple shear connections, such as a single plate shear tab welded to the column or girder, or double clip angles bolted to the beam web. Moment connections, where flanges are welded or bolted with flange plates, are used in moment frames.

Structural bolts are ASTM F3125 Grade A325 or A490, most often 3/4 in or 7/8 in diameter. Standard and oversized hole sizes come from AISC 360 Table J3.3. The values below follow the 2016 and later editions, which enlarged the standard hole for 1 in and larger bolts:

Bolt diameter, in (mm)Standard hole, in (mm)Oversized hole, in (mm)
3/4 (19.1)13/16 (20.6)15/16 (23.8)
7/8 (22.2)15/16 (23.8)1-1/16 (27.0)
1 (25.4)1-1/8 (28.6)1-1/4 (31.8)

Bolted joints are classified under the RCSC Specification for Structural Joints as snug-tight, pretensioned or slip-critical. Slip-critical faying surfaces must be left uncoated or given a qualified coating, so the drawing has to show where paint stops.

Tip: Confirm hole type, size and any slots before release. Holes are the one feature that cannot be fixed cleanly on site, and slotted holes in the wrong direction are a common cause of field rework.

Specifications that shape the order

  • Project specifications. Structural framing is usually specified under CSI MasterFormat Section 05 12 00 Structural Steel Framing, with joists, deck and miscellaneous metals in Sections 05 21 00, 05 31 00 and 05 50 00.
  • Design and fabrication standards. AISC 360 for design, the AISC Code of Standard Practice (AISC 303) for fabrication and erection practice, and AWS D1.1 for welding.
  • Coatings. Interior steel that will be fireproofed or concealed is often left unprimed, because primer adds little where steel stays dry and enclosed, and some spray-applied fireproofing products are tested only over bare steel or specific primers. Exterior and exposed steel is typically galvanized or painted, and steel left visible in the finished building may be specified as architecturally exposed; see architectural steel and aluminum.
  • Documentation. Mill test reports for each heat, and domestic origin records where public funding or owner policy requires them.

Structural steel processing at ASA

American Steel & Aluminum supplies structural fabricators and contractors with A36, A992, A709 and A588 shapes and processed components, including sawing and miter cutting, beam drilling and coping on a Voortman V807M coping system at West Bath, ME, angle punching, clip angles, base and connection plates, and plasma and oxy-fuel cut plate. Components are processed to the customer’s approved drawings with mill certifications and full material traceability available, and delivered on ASA’s own trucks across New England and New York. See our steel processing capabilities or call 1-800-933-7833.

Frequently asked questions

What is the most common steel grade for commercial building beams?

ASTM A992 is the standard grade for wide flange beams and columns in US building construction. It has a minimum yield strength of 50 ksi (345 MPa) and controlled chemistry for good weldability. Angles, channels and plate are commonly ASTM A36, and square and rectangular HSS is usually ASTM A500, with A1085 specified on some projects.

What do the numbers in a W-shape designation mean?

The first number is the nominal depth in inches and the second is the weight in pounds per linear foot. A W12x26 is nominally 12 in deep and weighs 26 lb per foot. Actual depth varies slightly from the nominal value within a size group, so detailers use the published dimensions in the AISC Steel Construction Manual for each shape.

Why are some steel beams cambered?

Camber is a slight upward curve put into a beam in the shop so it ends up close to level after the dead load of wet concrete and the floor is applied. It is common on longer composite floor beams. The engineer specifies the camber amount, and the fabricator or processor induces it, usually by cold bending the beam.

Are steel joists the same as steel beams?

No. Open web steel joists are lightweight trusses built from angles or bars, designed and manufactured by joist producers to Steel Joist Institute standards, and are common on roofs of single-story buildings. Steel beams are solid rolled shapes such as W-shapes. Joists are economical over long spans with uniform loads, while beams handle heavy, concentrated or irregular loads better.

Should structural steel for a commercial building be primed?

It depends on where the steel ends up. Steel that will be enclosed or fireproofed indoors is often delivered bare, since primer is unnecessary on steel that stays dry and can complicate fireproofing adhesion. Steel exposed to weather or left visible is usually painted or galvanized. The project specification governs, so check the coating section before ordering processed members.

Material, processing and fabrication from one supplier

Send a drawing or a material list and the ASA team will quote it from stock.