Steel racking is a structural system of upright frames, horizontal beams and bracing that stores loads off the floor, from pallets in a warehouse to batteries and equipment in an industrial building. In the US, industrial steel storage racks are designed to ANSI MH16.1, the specification published by the Rack Manufacturers Institute (RMI), which sets how racks are designed, tested, marked and used.
A rack looks simple, but it behaves like a tall, slender building frame with its connections loaded every time a forklift sets down a pallet. Good racking design balances capacity, stability, floor space and the cost of fabricating and installing hundreds of identical bays.
Types of steel racking
Rack type follows how loads are stored and retrieved. The main categories are below.
| Rack type | How it works | Typical use |
|---|---|---|
| Selective pallet rack | One pallet deep, every load reachable from the aisle | General warehousing with many SKUs |
| Drive-in and drive-through | Forklifts drive into the rack on rails | High density storage of a few SKUs |
| Push-back and pallet flow | Loads ride on carts or rollers, several deep | Dense storage with faster access than drive-in |
| Cantilever | Arms project from a central column with no front uprights | Long material such as bar, tube, lumber and shapes |
| Equipment and battery racks | Purpose built frames sized to the equipment they carry | Energy storage, electrical rooms, data centers |
Cantilever racks are covered by a separate standard, ANSI MH16.3. Equipment racks are often custom designs, and racks for energy storage carry extra requirements covered in our guide to battery rack manufacturing.
Anatomy of a rack assembly
Upright frames
Each upright frame is two columns joined by horizontal and diagonal braces, forming a truss in the cross-aisle direction. Columns carry a repeating hole or slot pattern so beam levels can be set at any height in fixed increments. The bracing pattern and the bolted or welded brace connections largely set the frame’s capacity.
Beams and connectors
Beams span between frames in the down-aisle direction and carry the load. They are usually formed box or step sections with welded end connectors that hook into the column holes. Each connection needs a locking device so a beam cannot be knocked upward out of its slots by a forklift.
Base plates and anchors
Columns sit on base plates anchored to the floor slab. The plates spread column load into the concrete and the anchors resist sliding, uplift and overturning, especially in seismic regions.
Accessories
Wire or steel decking, pallet supports, row spacers that tie back to back rows together, column protectors and end of aisle guards complete the system. Many of these are simple laser cut and formed parts, but they are ordered in large quantities.
Design standards: ANSI MH16.1 and RMI
ANSI MH16.1 is referenced by the International Building Code for steel storage racks, so in most jurisdictions it is the governing design document. Key points for buyers and fabricators:
- Member design. Hot rolled members are designed to AISC 360 and cold-formed members to AISI S100, with rack-specific provisions in MH16.1 for column perforations, connections and stability.
- Testing. Beam to column connections and perforated column sections are commonly qualified by test, because their behavior is hard to predict by calculation alone.
- Beam deflection. MH16.1 limits beam deflection under the rated product load to 1/180 of the span (L/180).
- Seismic design. Racks in seismic areas are designed for earthquake forces under the nonbuilding structures provisions of ASCE 7, which affects bracing, base plates and anchors.
- Load plaques. Installations must display permanent plaques showing the permissible load per level, so users know the limits of the system they have.
Rack design and the stamped calculations that support a permit are the job of the rack designer or engineer of record. The fabricator’s role is to build each component exactly to those drawings, since a change in steel grade, thickness or hole location can change the rated capacity.
Tip: Treat material grade and thickness on a rack drawing as part of the load rating. Approve any substitution through the rack engineer, even one that looks heavier, because it can change connection behavior.
Roll-formed vs structural racking
Most warehouse rack is made from roll-formed, cold-formed sections. Structural rack uses hot rolled channels and angles bolted together. Custom equipment racks often fall between the two, using press brake formed sections and welded frames.
| Feature | Roll-formed rack | Structural rack |
|---|---|---|
| Members | Cold-formed open or closed sections, punched | Hot rolled channels and angles, drilled or punched |
| Beam connection | Hooked connectors in a slot pattern | Bolted connections |
| Weight and cost | Lighter and lower cost per position | Heavier and higher cost |
| Damage resistance | More easily damaged by forklift impact | Better impact resistance |
| Best fit | General warehousing, frequent reconfiguration | Drive-in, heavy loads, freezers, high traffic |
Fabricating custom rack components
Custom racks and rack parts made in hundreds rather than hundreds of thousands are usually built with flexible processes instead of dedicated roll-forming tooling.
- Laser cutting produces column blanks with hole patterns, gussets, base plates and brackets directly from CAD, and a tube laser cuts slots and holes in tube columns and braces in one setup.
- Press brake forming makes channel and hat sections, shelf pans and decking from sheet. Hole patterns stay accurate when the holes are kept clear of the bend lines.
- Angle punching and sawing make braces, clip angles and structural members.
- Welding joins frames, beam connectors and base plates. Welded frames ship stiffer and install faster; bolted frames ship flat and cost less to transport.
- Finishing is usually powder coating for indoor racks and hot dip galvanizing or a coated steel for damp or outdoor locations.
Accuracy matters most in the features that repeat. Column hole pitch must stay consistent over the full height so beams sit level from one frame to the next, and welded frames must be square so the installed rack stands plumb. Cutting every hole in a column in one laser setup, and welding frames in fixtures, keeps those features consistent across a large order.
Designing for assembly and delivery
- Use one hole pattern, one bolt size and one material thickness across as many components as possible to reduce part numbers and installer errors.
- Decide early whether frames ship welded or knocked down; it changes packaging, freight and site labor.
- Kit hardware and accessories by bay or by row so installers receive complete sets.
- Mark parts with part numbers or color codes that match the installation drawings.
- Stage deliveries in installation sequence on large projects so the site is not storing the whole job at once.
Rack components and assemblies from ASA
American Steel & Aluminum fabricates rack components and welded rack assemblies to customer drawings, from laser cut and press brake formed parts to robotic welded frames and powder coated finishes. Material comes from stock carbon steel, galvanized and structural shapes, with mill certifications and full material traceability available. Kitting, kanban and JIT delivery support rack programs, with most orders delivered in 24 to 48 hours. Learn more about racking for energy storage.
Frequently asked questions
What is ANSI MH16.1?
ANSI MH16.1 is the Specification for the Design, Testing and Utilization of Industrial Steel Storage Racks, published by the Rack Manufacturers Institute. It covers member and connection design, testing of rack components, seismic considerations, load plaques and the safe use of rack systems. The International Building Code references it, so it is the governing design document for most storage racks in the US.
What does the RMI do?
The Rack Manufacturers Institute is a trade association of rack manufacturers in the US. It develops and maintains the ANSI MH16.1 specification for industrial steel storage racks and ANSI MH16.3 for cantilever racks, and publishes guidance on rack inspection, safe use and load plaques for owners, engineers and installers.
Do steel storage racks need to be anchored?
In most cases, yes. Anchoring each column base plate to the slab keeps frames from sliding or walking when hit and resists overturning, and it is essential in seismic regions. The rack designer specifies anchor size, embedment and quantity based on loads, frame height and slab conditions, so follow the stamped design rather than a rule of thumb.
Can rack beams be moved to different heights?
Beam levels on slotted uprights can be moved, but changing beam elevations changes the unbraced length of the columns and therefore the capacity of the whole frame. A move that looks small can lower the rated load. Check any reconfiguration against the rack manufacturer's capacity tables or have an engineer review it, then update the load plaques.
Is structural rack stronger than roll-formed rack?
Structural rack made from hot rolled channel is heavier and resists forklift impact better, which is why it is common in drive-in systems, freezers and high traffic areas. Roll-formed rack can be designed for the same rated loads at lower weight and cost. The right choice depends on load, traffic, damage risk and how often the layout will change.