On this page
A custom steel enclosure is a fabricated cabinet or box built to house electrical, control or mechanical equipment in a size and layout that catalog enclosures do not offer. Its design starts with the environment it must withstand, usually expressed as a NEMA 250 or UL 50E enclosure type, and that type drives the material, the seam construction, the gasketing and the finish.
Most custom enclosures are made from cold rolled carbon steel, stainless steel or aluminum sheet that is laser cut, formed on a press brake, welded, finished and fitted with doors and hardware. Getting the details right on the drawing matters more than any single process, because a gap in one corner can cost the enclosure its rating.
NEMA 250 and UL 50E enclosure types
NEMA 250 defines enclosure types for electrical equipment rated 1,000 volts maximum by the environmental protection they provide. UL 50 covers general construction requirements for enclosures, and UL 50E covers the environmental tests, such as rain, hose-down, dust and corrosion, that a listed enclosure must pass to carry a type rating. The most common nonhazardous types are below.
| Type | Location | Protects against |
|---|---|---|
| 1 | Indoor | Contact with live parts and falling dirt |
| 3R | Outdoor | Rain, sleet and snow; undamaged by external ice |
| 3 | Outdoor | Rain, sleet, snow and windblown dust; undamaged by external ice |
| 4 | Indoor or outdoor | Windblown dust and rain, splashing water and hose-directed water |
| 4X | Indoor or outdoor | Everything Type 4 covers, plus corrosion |
| 12 | Indoor | Circulating dust, lint, fibers and dripping noncorrosive liquids |
| 13 | Indoor | Dust, spraying water, oil and noncorrosive coolants |
Types 6 and 6P add protection against temporary and prolonged submersion, and Types 7 through 10 cover hazardous locations, which follow separate requirements. Outside North America, enclosures are often specified with IEC 60529 IP codes. NEMA types include tests that IP codes do not, such as corrosion and icing, so a NEMA type can be matched to a minimum IP code but an IP code cannot be converted back to a NEMA type.
Tip: A type rating belongs to an enclosure design that has been tested, not to a drawing. If the end product must be UL listed, confirm early who holds the listing and whether the fabricated enclosure needs to be built under that listing’s follow-up inspection program.
Choosing the material
Material follows the environment. Indoor industrial enclosures are usually painted carbon steel; washdown and corrosive sites move to stainless or aluminum.
| Material | Typical enclosure types | Notes |
|---|---|---|
| Cold rolled carbon steel, powder coated | 1, 12, 13, and 3R or 4 with a suitable finish | Lowest cost; flat surface takes powder coat well |
| Galvanized or galvannealed steel | 1, 3R, 12; internal panels | Zinc protects cut edges and the inside of the box; galvannealed paints well |
| 304 stainless | 4X, 12, 13 | Food, beverage and washdown areas; can be left unpainted |
| 316 stainless | 4X | Coastal, marine, chemical and chloride exposure |
| 5052 aluminum | 3R, 4, 4X | About one third the weight of steel, good corrosion resistance outdoors |
For a deeper look at the two stainless grades, see 304 vs 316 stainless steel. Keep in mind that galvanic corrosion can occur where aluminum enclosures meet steel mounting hardware, so stainless or plated fasteners and insulating washers are often specified.
Common gauges
Wall thickness is set by enclosure size, door span and what mounts to the walls. Stainless gauge numbers are slightly thicker than carbon steel at the same number, which matters when you switch a design between materials.
| Gauge | Carbon steel, in (mm) | Stainless, in (mm) | Typical use |
|---|---|---|---|
| 16 | 0.0598 (1.52) | 0.0625 (1.59) | Small wall mount boxes, junction boxes, covers |
| 14 | 0.0747 (1.90) | 0.0781 (1.98) | Medium wall mount and pedestal enclosures, doors |
| 12 | 0.1046 (2.66) | 0.1094 (2.78) | Large floor standing enclosures and frames |
| 10 | 0.1345 (3.42) | 0.1406 (3.57) | Bases, lifting frames, heavy mounting rails |
Values are nominal; see the sheet metal gauge chart for coated steel and aluminum.
Design features that decide performance
Seams and corners
Type 4 and 4X enclosures generally need continuously welded seams, ground smooth on the outside so water and debris cannot collect. Type 1 and some Type 12 designs can use formed and spot welded or riveted corners, which cost less. Corner design should be settled before the flat patterns are drawn, since it changes every blank.
Door flanges and gaskets
The door seals against a formed return flange on the body, compressing a gasket held in a channel or bonded to the door. A drip lip or collar over the top edge keeps water from sitting on the gasket line. Gasket compression depends on flange flatness and door stiffness, so large doors usually get welded stiffeners.
Hardware, mounting panels and grounding
Self-clinching studs and nuts installed after forming give threads in thin sheet without welding. Back mounting panels, often galvanized or painted white for visibility, carry components on studs welded or clinched to the rear wall. Ground studs and bonding points must be masked during powder coating so they make metal to metal contact.
Ventilation and cooling
Louvers and fan openings reduce the protection an enclosure can offer, so ventilated designs are usually limited to Type 1 or 3R unless filtered fans, air conditioners or heat exchangers rated for the type are used. Plan cutouts for these units on the original drawing.
How a custom enclosure is fabricated
- Cutting. Fiber laser cutting produces the body, door and panel blanks with cutouts, knockouts and louvers in one setup.
- Forming. CNC press brakes form flanges, return lips and door pans. Bend order matters on deep boxes with four sides.
- Welding. Corners and seams are TIG or MIG welded, then ground and blended. Stainless welds are cleaned or passivated to restore corrosion resistance.
- Hardware insertion. Studs, nuts and standoffs are pressed in after forming and before finishing.
- Finishing. Carbon steel is pretreated and powder coated; stainless is often left with a brushed or mill finish.
- Assembly. Gaskets, hinges, latches, mounting panels and any windows or cooling units are installed and the door is adjusted for even compression.
DFM tips for enclosure drawings
- Use one material thickness and one inside bend radius for the whole body where possible.
- Keep the edge of each round hole at least 2.5 times material thickness plus the inside bend radius from a bend, and give slots and large cutouts more room. This common rule of thumb prevents distortion.
- Show the gasket type and compression target, and which surfaces must stay uncoated.
- Specify the enclosure type and the environment, not just the construction, so the fabricator can flag details that conflict with the rating.
- Locate cutouts for operators, meters and HMIs from a common datum on the door.
Custom enclosures from ASA
American Steel & Aluminum fabricates enclosures to customer drawings from stocked cold rolled, galvanized and galvannealed steel, 304 and 316 stainless and 5052 aluminum. Parts are cut on an 8 kW Trumpf fiber laser, formed on CNC press brakes, welded and finished with powder coating under one ISO 9001:2015 certified quality management system. See our precision sheet metal manufacturing capabilities or call 1-800-933-7833.
Frequently asked questions
What is the difference between NEMA 4 and NEMA 4X?
Both types protect against windblown dust and rain, splashing water and hose-directed water, and both are suitable indoors or outdoors. NEMA 4X adds corrosion resistance, which is why 4X enclosures are usually built from stainless steel or aluminum rather than painted carbon steel. Food processing, wastewater and coastal sites commonly specify 4X.
Is a NEMA 3R enclosure waterproof?
No. A NEMA 3R enclosure keeps out falling rain, sleet and snow and is not damaged by ice forming on the outside, but it is not tested against hose-directed water or dust. Many 3R designs include ventilation openings. If equipment will be hosed down or exposed to blowing dust, specify Type 4 or 4X instead.
Can a fabricator build an enclosure to a UL type rating?
A fabricator can build an enclosure with the construction details a type rating calls for, such as welded seams and gasketed doors. The rating itself comes from testing to UL 50E and a listing program, so a listed enclosure must be produced under the listing holder's program. Confirm who will hold the listing before production starts.
How thick should a custom steel enclosure be?
Small wall mount enclosures commonly use 16 gauge steel, medium enclosures and doors 14 gauge, and large floor standing enclosures 12 gauge, with heavier material for bases and lifting frames. The right gauge depends on overall size, door span, mounted component weight and whether the enclosure must resist impact or vandalism.
Should a custom enclosure be stainless steel or powder coated carbon steel?
Powder coated carbon steel is the lower cost choice for dry indoor locations and many outdoor ones. Stainless steel is the better choice where enclosures are washed down, exposed to chemicals or salt air, or must avoid coating damage that exposes bare steel. 304 suits most washdown areas, and 316 is preferred near the coast or with chlorides.